   1               /MI8-EC (TC08 DECtape)
   2               DTLA=6766       / LOAD REGISTER A
   3               DTSF=6771       / SKIP ON FLAGS
   4               DTLB=6774       / LOAD REGISTER B
   5                       FIELD   0
   6                       *7554
   7 007554  7600  START,  7600            / CLA; ALSO LOADING ADDRESS, AND COUNT
   8 007555  6774          DTLB            / TRANSFER TO FIELD 0
   9 007556  1374          TAD MOVE        / GET A MOVE COMMAND
  10 007557  6766          DTLA            / MOVE
  11 007560  6771          DTSF            / WAIT FOR IT
  12 007561  5360          JMP .-1
  13 007562  7240          CLA CMA         / GET LOADING ADDRESS - 1
  14 007563  1354          TAD START
  15 007564  3773          DCA I IDCA      / SET CA
  16 007565  1354          TAD START       / GET COUNT
  17 007566  3772          DCA I IDWC      / SET WC
  18 007567  1375          TAD READ        / GET A READ COMMAND
  19 007570  6766          DTLA            / READ
  20 007571  5376          JMP WAIT        / GO WAIT
  21 007572  7754  IDWC,   7754            / PTR TO WC
  22 007573  7755  IDCA,   7755            / PTR TO CA
  23 007574  0600  MOVE,   0600            / MOVE, NORMAL, GO
  24 007575  0220  READ,   0220            / READ, GO
  25 007576  6771  WAIT,   DTSF            / WAIT FOR THE READ
  26 007577  5376          JMP .-1
  27               / WHEN THE READ IS FINISHED, FALL THROUGH ONTO THE NEWLY LOADED CODE.
  28                       *7600
  29 007600  7777          7777            / REPLACED BY THE LOADED CODE.
  30 007601  7777          7777            / (ALL DIODES REMOVED)
  31 007602  7777          7777
  32 007603  7777          7777
  33 007604  7777          7777
  34 007605  7777          7777
  35 007606  7777          7777
  36 007607  7777          7777
  37 007610  7777          7777
  38 007611  7777          7777
  39 007612  7777          7777
  40 007613  7777          7777
  41               $