   1               /MI8-EF (Edu Sys Low)
   2               CAF=6007        / CLEAR ALL FLAGS
   3               DTLA=6766       / LOAD REGISTER A
   4               DTSF=6771       / SKIP ON FLAGS
   5               DMAR=6603       / START READ
   6               DFSC=6622       / SKIP IF DONE
   7                       FIELD   0
   8                       *7737
   9 007737  6007  START,  CAF                     / INITIALIZE
  10 007740  7604          LAS                     / READ THE SWITCHES
  11 007741  7510          SPA                     / BIT 0 SET?
  12 007742  3343          DCA .+1                 / YES, USE IT INSTEAD
  13 007743  6766  L07743, DTLA                    / MOVE DECTAPE
  14 007744  6771          DTSF                    / WAIT FOR IT
  15 007745  5344          JMP .-1
  16               / THE READ COMMAND WILL REPLACE THIS CODE
  17               / THE SECOND TIME THROUGH.
  18 007746  1376          TAD P07776              / GET READ COMMAND
  19 007747  5343          JMP L07743              / GO DO IT
  20               / DF32 BOOT
  21 007750  7600          7600                    / CLA, ALSO WORD COUNT!
  22 007751  6603          DMAR                    / START A READ, ALSO CA!
  23 007752  6622          DFSC                    / WAIT FOR IT
  24 007753  5352          JMP .-1
  25 007754  5752          JMP I .-2               / JUMP INTO THE NEW CODE
  26 007755  7577          7577                    / UNUSED
  27               / THIS REST IS JUST THE HIGH SPEED RIM LOADER.
  28 007756  6014  L07756, RFC                     / FETCH FROM LSR
  29 007757  6011  L07757, RSF                     / SKIP IF READY
  30 007760  5357          JMP .-1
  31 007761  6016  D07761, RRB RFC                 / GET HIGH 6 BITS
  32 007762  7106          CLL RTL                 / SHIFT UP
  33 007763  7006          RTL 
  34 007764  7510          SPA                     / CHECK FOR LEADER
  35 007765  5374          JMP L07774              / IGNORE LEADER
  36 007766  7006          RTL                     / FINISH SHIFT UP
  37 007767  6011  L07767, RSF                     / WAIT FOR LOW 6 BITS
  38 007770  5367          JMP .-1
  39 007771  6016  D07771, RRB RFC                 / OR THEM IN
  40 007772  7420          SNL                     / LOCATION OR DATA?
  41 007773  3776          DCA I P07776            / DATA
  42 007774  3376  L07774, DCA P07776              / LOCATION
  43 007775  5357          JMP L07757              / GO LOOK FOR MORE
  44 007776  0220  P07776, 220                     / SAVED LOCATION (OR 0)
  45               $